Agilent 1100 G1365B Multi-Wavelength Detector
The Agilent 1100 HPLC G1365B Multi-Wavelength Detector is a dedicated MWD that offers excellent sensitivity for both single and multiple wavelength detection. This MWD utilizes deuterium and tungsten lamps with a wavelength range of 190 to 950 nm, offering an expanded detection range with lowest detection limit. The G1365B’s diode array design enables simultaneous acquisition of up to eight compound-specific wavelengths for increased sensitivity and selectivity. The programmable slit (1 to 16 nm) also allows rapid optimization of sensitivity, linearity, and spectral resolution.
Agilent 1100 G1365B Multi-Wavelength Detector Specifications
Detection Type | 1024-element photodiode array |
Light Source | Deuterium and tungsten lamps |
Wavelength Range | 190 – 950 nm |
Short Term Noise (ASTM) Single and Multi-Wavelength | ± 1 × 10-5AU at 254 and 750 nm |
Drift | 2 × 10-3AU/hr at 254 nm |
Linear Absorbance Range | > 2 AU (upper limit) |
Wavelength Accuracy | ± 1 nm |
Wavelength Bunching | 1 – 400 nm |
Slit Width | 1, 2, 4, 8, 16 nm |
Diode Width | < 1 nm |
Flow Cells | Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum High pressure: 1.7 µl volume, 6 mm cell path length and 400 bar (5880 psi) pressure maximum 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum |
Control and Data Evaluation | Agilent ChemStation for LC |
Analog Outputs | Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs |
Communications | Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional |
Safety and Maintenance | Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. |
GLP Features | Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter |
Housing | All materials recyclable. |
Refurbished instruments information
If you find a product which is of interest for your lab, please ask for more information and
we will send you more photos and details about the instrument. If your lab is nearby or you are
making a trip to the Uppsala-Stockholm region in Sweden, please pay us a visit and investigate our stock
of instruments yourself!
Knivsta is situated just between Uppsala and Arlanda airport, 15 minutes by car to either
and 30 – 40 minutes by car from Stockholm.
Instrument condition:
All refurbished instruments and complete analytical systems from Elsichrom are thoroughly tested
in our own lab before delivery. All functions are tested to specifications and printed test results
are enclosed. As an extra safety precaution you as a customer get 3 months function warranty.
Shipping:
Within Scandinavia with DPD in boxes or on pallet, depending on size of shipment.
International shipping is done via truck, air freight or DPD, whichever is most convenient
for the customer. In connection with an order, we will send you a shipping cost quotation
before any delivery takes place.
Delivery time:
Normally 5 – 10 days depending on size of order.
Payment terms:
Order can be paid directly via internet transfer to Elsichrom. All details can be found on
the proforma invoice. Shipment is done immediately after prepayment.